pull/557/merge
mcarbonne 1 month ago committed by GitHub
commit 88c8bc4758
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194

@ -3,59 +3,32 @@ package database
import (
"context"
"fmt"
"strings"
"time"
"github.com/analogj/scrutiny/webapp/backend/pkg/models/collector"
"github.com/analogj/scrutiny/webapp/backend/pkg/models/measurements"
influxdb2 "github.com/influxdata/influxdb-client-go/v2"
"strings"
"time"
)
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
// Temperature Data
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
func (sr *scrutinyRepository) SaveSmartTemperature(ctx context.Context, wwn string, deviceProtocol string, collectorSmartData collector.SmartInfo) error {
if len(collectorSmartData.AtaSctTemperatureHistory.Table) > 0 {
for ndx, temp := range collectorSmartData.AtaSctTemperatureHistory.Table {
//temp value may be null, we must skip/ignore them. See #393
if temp == 0 {
continue
}
minutesOffset := collectorSmartData.AtaSctTemperatureHistory.LoggingIntervalMinutes * int64(ndx) * 60
smartTemp := measurements.SmartTemperature{
Date: time.Unix(collectorSmartData.LocalTime.TimeT-minutesOffset, 0),
Temp: temp,
}
tags, fields := smartTemp.Flatten()
tags["device_wwn"] = wwn
p := influxdb2.NewPoint("temp",
tags,
fields,
smartTemp.Date)
err := sr.influxWriteApi.WritePoint(ctx, p)
if err != nil {
return err
}
}
// also add the current temperature.
} else {
smartTemp := measurements.SmartTemperature{
Date: time.Unix(collectorSmartData.LocalTime.TimeT, 0),
Temp: collectorSmartData.Temperature.Current,
}
// collectorSmartData.AtaSctTemperatureHistory isn't reliable, only use current temperature
tags, fields := smartTemp.Flatten()
tags["device_wwn"] = wwn
p := influxdb2.NewPoint("temp",
tags,
fields,
smartTemp.Date)
return sr.influxWriteApi.WritePoint(ctx, p)
smartTemp := measurements.SmartTemperature{
Date: time.Unix(collectorSmartData.LocalTime.TimeT, 0),
Temp: collectorSmartData.Temperature.Current,
}
return nil
tags, fields := smartTemp.Flatten()
tags["device_wwn"] = wwn
p := influxdb2.NewPoint("temp",
tags,
fields,
smartTemp.Date)
return sr.influxWriteApi.WritePoint(ctx, p)
}
func (sr *scrutinyRepository) GetSmartTemperatureHistory(ctx context.Context, durationKey string) (map[string][]measurements.SmartTemperature, error) {

Loading…
Cancel
Save