retrieve all device data. SAS devices do not return power on hours when using `-a` flag (unlike other device types).

fixes #43
fixes #9
pull/51/head
Jason Kulatunga 4 years ago
parent 75a5f7dfb6
commit cb0aa9823e

@ -68,7 +68,7 @@ analogj/scrutiny
- `/run/udev` is necessary to provide the Scrutiny collector with access to your device metadata
- `--cap-add SYS_RAWIO` is necessary to allow `smartctl` permission to query your device SMART data
- NOTE: If you have NVMe drives, you must use `--cap-add SYS_ADMIN` instead. See [#26](https://github.com/AnalogJ/scrutiny/issues/26)
- NOTE: If you have NVMe drives, you must use `--cap-add SYS_ADMIN` instead. See issue [#26](https://github.com/AnalogJ/scrutiny/issues/26#issuecomment-696817130)
- `--device` entries are required to ensure that your hard disk devices are accessible within the container
- `analogj/scrutiny` is a omnibus image, containing both the webapp server (frontend & api) as well as the S.M.A.R.T metric collector. (see below)

@ -105,7 +105,7 @@ func (mc *MetricsCollector) Collect(deviceWWN string, deviceName string, deviceT
//defer wg.Done()
mc.logger.Infof("Collecting smartctl results for %s\n", deviceName)
args := []string{"-a", "-j"}
args := []string{"-x", "-j"}
//only include the device type if its a non-standard one. In some cases ata drives are detected as scsi in docker, and metadata is lost.
if len(deviceType) > 0 && deviceType != "scsi" && deviceType != "ata" {
args = append(args, "-d", deviceType)

Loading…
Cancel
Save