package detect
|
|
|
|
import (
|
|
"encoding/json"
|
|
"fmt"
|
|
"github.com/analogj/scrutiny/collector/pkg/common/shell"
|
|
"github.com/analogj/scrutiny/collector/pkg/config"
|
|
"github.com/analogj/scrutiny/collector/pkg/models"
|
|
"github.com/analogj/scrutiny/webapp/backend/pkg/models/collector"
|
|
"github.com/sirupsen/logrus"
|
|
"os"
|
|
"strings"
|
|
)
|
|
|
|
type Detect struct {
|
|
Logger *logrus.Entry
|
|
Config config.Interface
|
|
Shell shell.Interface
|
|
}
|
|
|
|
//private/common functions
|
|
|
|
// This function calls smartctl --scan which can be used to detect storage devices.
|
|
// It has a couple of issues however:
|
|
// - --scan does not return any results on mac
|
|
//
|
|
// To handle these issues, we have OS specific wrapper functions that update/modify these detected devices.
|
|
// models.Device returned from this function only contain the minimum data for smartctl to execute: device type and device name (device file).
|
|
func (d *Detect) SmartctlScan() ([]models.Device, error) {
|
|
//we use smartctl to detect all the drives available.
|
|
args := strings.Split(d.Config.GetString("commands.metrics_scan_args"), " ")
|
|
detectedDeviceConnJson, err := d.Shell.Command(d.Logger, d.Config.GetString("commands.metrics_smartctl_bin"), args, "", os.Environ())
|
|
if err != nil {
|
|
d.Logger.Errorf("Error scanning for devices: %v", err)
|
|
return nil, err
|
|
}
|
|
|
|
var detectedDeviceConns models.Scan
|
|
err = json.Unmarshal([]byte(detectedDeviceConnJson), &detectedDeviceConns)
|
|
if err != nil {
|
|
d.Logger.Errorf("Error decoding detected devices: %v", err)
|
|
return nil, err
|
|
}
|
|
|
|
detectedDevices := d.TransformDetectedDevices(detectedDeviceConns)
|
|
|
|
return detectedDevices, nil
|
|
}
|
|
|
|
//updates a device model with information from smartctl --scan
|
|
// It has a couple of issues however:
|
|
// - WWN is provided as component data, rather than a "string". We'll have to generate the WWN value ourselves
|
|
// - WWN from smartctl only provided for ATA protocol drives, NVMe and SCSI drives do not include WWN.
|
|
func (d *Detect) SmartCtlInfo(device *models.Device) error {
|
|
fullDeviceName := fmt.Sprintf("%s%s", DevicePrefix(), device.DeviceName)
|
|
args := strings.Split(d.Config.GetCommandMetricsInfoArgs(fullDeviceName), " ")
|
|
//only include the device type if its a non-standard one. In some cases ata drives are detected as scsi in docker, and metadata is lost.
|
|
if len(device.DeviceType) > 0 && device.DeviceType != "scsi" && device.DeviceType != "ata" {
|
|
args = append(args, "--device", device.DeviceType)
|
|
}
|
|
args = append(args, fullDeviceName)
|
|
|
|
availableDeviceInfoJson, err := d.Shell.Command(d.Logger, d.Config.GetString("commands.metrics_smartctl_bin"), args, "", os.Environ())
|
|
if err != nil {
|
|
d.Logger.Errorf("Could not retrieve device information for %s: %v", device.DeviceName, err)
|
|
return err
|
|
}
|
|
|
|
var availableDeviceInfo collector.SmartInfo
|
|
err = json.Unmarshal([]byte(availableDeviceInfoJson), &availableDeviceInfo)
|
|
if err != nil {
|
|
d.Logger.Errorf("Could not decode device information for %s: %v", device.DeviceName, err)
|
|
return err
|
|
}
|
|
|
|
//WWN: this is a serial number/world-wide number that will not change.
|
|
//DeviceType and DeviceName are already populated, however may change between collector runs (eg. config/host restart)
|
|
//InterfaceType:
|
|
device.ModelName = availableDeviceInfo.ModelName
|
|
device.InterfaceSpeed = availableDeviceInfo.InterfaceSpeed.Current.String
|
|
device.SerialNumber = availableDeviceInfo.SerialNumber
|
|
device.Firmware = availableDeviceInfo.FirmwareVersion
|
|
device.RotationSpeed = availableDeviceInfo.RotationRate
|
|
device.Capacity = availableDeviceInfo.UserCapacity.Bytes
|
|
device.FormFactor = availableDeviceInfo.FormFactor.Name
|
|
device.DeviceProtocol = availableDeviceInfo.Device.Protocol
|
|
if len(availableDeviceInfo.Vendor) > 0 {
|
|
device.Manufacturer = availableDeviceInfo.Vendor
|
|
}
|
|
|
|
//populate WWN is possible if present
|
|
if availableDeviceInfo.Wwn.Naa != 0 { //valid values are 1-6 (5 is what we handle correctly)
|
|
d.Logger.Info("Generating WWN")
|
|
wwn := Wwn{
|
|
Naa: availableDeviceInfo.Wwn.Naa,
|
|
Oui: availableDeviceInfo.Wwn.Oui,
|
|
Id: availableDeviceInfo.Wwn.ID,
|
|
}
|
|
device.WWN = strings.ToLower(wwn.ToString())
|
|
d.Logger.Debugf("NAA: %d OUI: %d Id: %d => WWN: %s", wwn.Naa, wwn.Oui, wwn.Id, device.WWN)
|
|
} else {
|
|
d.Logger.Info("Using WWN Fallback")
|
|
d.wwnFallback(device)
|
|
}
|
|
if len(device.WWN) == 0 {
|
|
// no WWN populated after WWN lookup and fallback. we need to throw an error
|
|
errMsg := fmt.Sprintf("no WWN (or fallback) populated for device: %s. Device will be registered, but no data will be published for this device. ", device.DeviceName)
|
|
d.Logger.Errorf(errMsg)
|
|
return fmt.Errorf(errMsg)
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
// function will remove devices that are marked for "ignore" in config file
|
|
// will also add devices that are specified in config file, but "missing" from smartctl --scan
|
|
// this function will also update the deviceType to the option specified in config.
|
|
func (d *Detect) TransformDetectedDevices(detectedDeviceConns models.Scan) []models.Device {
|
|
groupedDevices := map[string][]models.Device{}
|
|
|
|
for _, scannedDevice := range detectedDeviceConns.Devices {
|
|
|
|
deviceFile := strings.ToLower(scannedDevice.Name)
|
|
|
|
detectedDevice := models.Device{
|
|
HostId: d.Config.GetString("host.id"),
|
|
DeviceType: scannedDevice.Type,
|
|
DeviceName: strings.TrimPrefix(deviceFile, DevicePrefix()),
|
|
}
|
|
|
|
//find (or create) a slice to contain the devices in this group
|
|
if groupedDevices[deviceFile] == nil {
|
|
groupedDevices[deviceFile] = []models.Device{}
|
|
}
|
|
|
|
// add this scanned device to the group
|
|
groupedDevices[deviceFile] = append(groupedDevices[deviceFile], detectedDevice)
|
|
}
|
|
|
|
//now tha we've "grouped" all the devices, lets override any groups specified in the config file.
|
|
|
|
for _, overrideDevice := range d.Config.GetDeviceOverrides() {
|
|
overrideDeviceFile := strings.ToLower(overrideDevice.Device)
|
|
|
|
if overrideDevice.Ignore {
|
|
// this device file should be deleted if it exists
|
|
delete(groupedDevices, overrideDeviceFile)
|
|
} else {
|
|
//create a new device group, and replace the one generated by smartctl --scan
|
|
overrideDeviceGroup := []models.Device{}
|
|
|
|
if overrideDevice.DeviceType != nil {
|
|
for _, overrideDeviceType := range overrideDevice.DeviceType {
|
|
overrideDeviceGroup = append(overrideDeviceGroup, models.Device{
|
|
HostId: d.Config.GetString("host.id"),
|
|
DeviceType: overrideDeviceType,
|
|
DeviceName: strings.TrimPrefix(overrideDeviceFile, DevicePrefix()),
|
|
})
|
|
}
|
|
} else {
|
|
//user may have specified device in config file without device type (default to scanned device type)
|
|
|
|
//check if the device file was detected by the scanner
|
|
var deviceType string
|
|
if scannedDevice, foundScannedDevice := groupedDevices[overrideDeviceFile]; foundScannedDevice {
|
|
if len(scannedDevice) > 0 {
|
|
//take the device type from the first grouped device
|
|
deviceType = scannedDevice[0].DeviceType
|
|
} else {
|
|
deviceType = "ata"
|
|
}
|
|
|
|
} else {
|
|
//fallback to ata if no scanned device detected
|
|
deviceType = "ata"
|
|
}
|
|
|
|
overrideDeviceGroup = append(overrideDeviceGroup, models.Device{
|
|
HostId: d.Config.GetString("host.id"),
|
|
DeviceType: deviceType,
|
|
DeviceName: strings.TrimPrefix(overrideDeviceFile, DevicePrefix()),
|
|
})
|
|
}
|
|
|
|
groupedDevices[overrideDeviceFile] = overrideDeviceGroup
|
|
}
|
|
}
|
|
|
|
//flatten map
|
|
detectedDevices := []models.Device{}
|
|
for _, group := range groupedDevices {
|
|
detectedDevices = append(detectedDevices, group...)
|
|
}
|
|
|
|
return detectedDevices
|
|
}
|